The Guardmaster® MSR125H/HP is a logic unit for monitoring and interfacing two-hand control devices with a safety-related circuit. This unit is used with mechanical switches and Bulletin 800Z Zero-Force Touch Buttons™.

The MSR125H/HP has 2 N.O. safety outputs. The safety outputs have independent and redundant internal contacts to help ensure the safety function.

The MSR125H/HP requires the two switches to be operated within 0.5 seconds of each other and will only authorize the ON state while both switches are held down. If one of the switches is released, the output goes to the OFF state and the machine cannot be restarted until both buttons are released and then operated simultaneously.

The MSR125H/HP conforms to EN574 Category IIIC, which gives specific requirements for two hand control units and logic devices. The MSR125H has fixed terminals and the MSR125HP has removable terminals.

  1. Category 4 per EN 954-1
  2. Safety category IIIC per EN 574
  3. Two-hand control unit
  4. Two N.O. safety outputs
  5. Fixed or removable terminals
  6. 22.5 mm wide housing

Note: Guardmaster Safety Relays have been marketed by Rockwell Automation under the trade name "Minotaur" in the past.

Specs

Safety Ratings
Standards EN 574, EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS 4024.1
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ⋆  PFHD: < 1.44 x 10-9
Note: For up-to-date information, visithttp://www.ab.com/safety/ MTTFd: > 385 years
  Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, and BG
Power Supply
Input Power Entry 24V DC, 24V AC, 115V AC, 230V AC
Power Consumption 2 W
Inputs
Safety Inputs 1 N.C. + 1 N.O.
Input Simultaneity <0.5 sec
Input Resistance, Max. 40 W
Reset Automatic
Power On Delay/ 1 second/500 ms
Recovery Time
Response Time 20 ms
Outputs
Safety Contacts 2 N.O.
Thermal CurrentIlth 1 x 6 A or 2 x 4 A nonswitching
Rated Impulse withstand Voltage 2500V
Switching Current @ Voltage, Min. 10 mA/10V
Fuses, Output External 6 A slow blow or 10 A fast acting
Electrical Life (Operations) (With surge suppression)
250V AC/6 A/1500VA cosf = 0.35…0.1 M
250V AC/2.5 A/625VA cosf = 0.6…0.5 M
250V AC/1.5 A/375VA cosf = 0.35…0.3 M
250V AC/5 A/1250VA cosf = 0.6…0.1 M
24V DC/2 A/48 W = 1 M
10V DC/0.01 A/0.1 W = 2 M
Mechanical Life 2,000,000 operations
Utilization Category
Resistive: AC-1 8 A @ 250V AC  
Resistive: DC-1 6 A/24V DC  
Inductive: AC-15 6 A @ 250V AC 6 A @ 125V AC
Inductive: DC-13 3 A/24V DC 6 A/24V DC @ 6 ops/min
Resistive UL: B300, R300, 8 A/250V AC, 6 A/24V DC, 30V DC Resistive
Environmental and Physical Characteristics
Enclosure Type Rating/ IP40 (NEMA 1), DIN 0470/
Terminal Protection IP20, DIN 0470
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 24V DC: 210 (0.46); 115/230V AC: 260 (0.57)
Conductor Size, Max. 0.2…4 mm2 (24…12 AWG)

⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years

Ask the Experts


Your Name (*)

Please let us know your name.
Your Email (*)

Please let us know your email address.
Message (*)

Please let us know your message.
Enter code in box provide (*)
Enter code in box provide

Invalid Input



LinkedIn

Copyright © ATC Automation Limited 2012. All Rights Reserved.

Design by Inspiration