MSR35H/HP

Documentation

Description

Overview

The Guardmaster® MSR35H/HP is a microprocessor-based, two-hand control monitoring safety relay, with safety-rated, solid-state outputs.

The input of the MSR35H/HP accepts two switches, each containing one normally open and one normally closed. Both switches must be actuated within 0.5 seconds of each other.

The MSR35 can alternatively be wired with two switches with normally open contacts to a Category IIIA application per EN 574.

The reset capability of the MSR35H/HP allows it to be set up for manual or automatic reset.

The outputs include two normally-open safety-rated outputs that can be connected to loads up to 2 A at 24V DC. These outputs can be used to send a safety stop signal to a machine or manufacturing system.

The MSR35H/HP also has one solid-state normally-closed auxiliary output, which must only be used to indicate the status of the MSR35H/HP

  1. Category 4 per EN 954-1
  2. Category IIIC or IIIA per EN 574
  3. Two solid-state safety outputs
  4. One solid-state auxiliary output
  5. Two-hand control input

Products

  1. MSR35H Two-Hand Control Monitoring Relays with Fixed Terminals
  2. MSR35HP Two-Hand Control Monitoring Relays with Removable Terminals

Certifications

  1. CE Marked for all applicable directives, cULus, c-Tick, and TÜV

 

Note: Guardmaster Safety Relays have been marketed by Rockwell Automation under the trade name "Minotaur" in the past.

Specs

Safety Ratings
Standards EN 954-1, ISO 13849-1, EN 574, IEC/EN 60204-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1
Functional Safety Data ⋆  PFHD: < 9.2 x 10-10
Note: For up-to-date information, visithttp://www.ab.com/safety/ MTTFd: > 631 years
  Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the architecture and application characteristics
Certifications CE Marked for all applicable directives, cULus, c-Tick, and TÜV
Power Supply
Input Power Entry 24V DC SELV
Power Consumption 3 W
Inputs
Safety Inputs 1 N.C. & 1 N.O. or 2 N.O.
Input Simultaneity 0.5 s
Input Resistance, Max. 200 W
Reset Automatic
Power On Delay/ 3 seconds/20 ms
Recovery Time
Response Time 15 ms
Outputs
Safety Contacts 2 N.O., 2 A @ 24V DC
Auxiliary Contacts 1 N.O., 50 mA @ 24V DC
Fuses, Output External 6 A slow blow or 10 A fast acting
Power LED Diagnostics 3 s Blink: Initialization
Constant: Normal Operation
2 Blinks: Configuration change during operation
4 Blinks: Solid state output switch fault
Continuous blinking: Internal fault
Environmental and Physical Characteristics
Enclosure Type Rating/ IP40 (NEMA 1), DIN 0470/
Terminal Protection IP20, DIN 0470
Operating Temperature [C (F)] -5…+55 ° (23…131 °)
Vibration 10…55 Hz, 0.35 mm
Shock 10 g, 16 ms, 100 shocks
Mounting 35 mm DIN Rail
Weight [g (lb)] 130 (0.287)
Conductor Size, Max. 0.2…2.5 mm2 (24…14 AWG)

⋆ Usable for ISO 13849-1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years



 

Ask the Experts


Your Name (*)

Please let us know your name.
Your Email (*)

Please let us know your email address.
Message (*)

Please let us know your message.
Enter code in box provide (*)
Enter code in box provide

Invalid Input



LinkedIn

Copyright © ATC Automation Limited 2012. All Rights Reserved.

Design by Inspiration